Prolink Giant Series (3P/1P) Tower
true online double conversion UPS systems are using Galvanic Isolation design to withstand all kinds of loads. The UPS applies an advanced digital controller to control the double conversion system, and with an isolated transformer at the output to protect the load and the UPS itself. The system has unique ventilation design for effective heat dissipation. All internal PCBAs are coated to withstand harsh environment. The unit is able to accept wide input voltage and frequency range to withstand robust environment. Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. Giant (3P/1P) series are available in models ranging from 6kVA to 10kVA.
Key Features
• Galvanic isolation design to withstand all kinds of loads
• Output power factor 0.8
• Fully coating PCBAs to withstand harsh environment
• Unique ventilation design for effective heat dissipation
• Wide input voltage and frequency range to withstand robust environment
• High short-circuit and overload capabilities
• Maintenance bypass switch (option)
• WIDE INPUT VOLTAGE AND FREQUENCY RANGE TO WITHSTAND ROBUST ENVIRONMENT
Rear Panel 6-10KVA
1. Intelligent slot
2. External battery connector
3. RS-232 communication port
4. Dry contact port
5. USB communication port
6. Emergency power off function connector (EPO connector)
7. Maintenance bypass switch (option)
8. Output Breaker
9. Bypass Breaker
10. Input circuit breaker
11. Out put/Bypass/Input terminal
12. Cooling fan
SPECIFICATIONS PRO63110-S/L 10KVA
GENERAL
– UPS Type : Tower
– Phase : 3-phase in / 1-phase out
– Rating (VA) : 10000VA
– Nominal Power (W) : 8000W
– Standard Model Dimension (mm) : 562 x 300 x 830 (D x W x H)
– Weight (kg) : 160
– Long-run Model Dimension (mm) : 562 x 300 x 830 (D x W x H)
– Weight (kg) : 115
INPUT
– Connection Type : Terminal
– Nominal Voltage : 3 x 360VAC / 380VAC / 400VAC (3Ph + G or 3Ph + N + G)
– Voltage Range : 286VAC ~ 476VAC @ 16 pcs of batteries 320VAC ~ 476VAC @ 18 pcs of batteries
– Frequency Range : 40 Hz ~ 55 Hz @ 50Hz system 57 Hz ~ 63 Hz @ 60Hz system
OUTPUT
– Connection Type : Terminal
– Output Voltage : 208VAC / 220VAC / 230VAC /240VAC (Selectable)
– Voltage Regulation : ±1%
– Frequency Range (Synchronized Range) : 50 Hz
– Frequency Synchronisation Speed : 1~2 Hz/s
– Current Crest Ratio : 3:1
– Harmonic Distortion : ≦3% THD (Linear load) ≦5% THD (Non-linear load)
BYPASS
– Connection Type : Terminal
– Input Voltage Range : 165VAC ~ 275VAC @ 16 pcs of batteries 185VAC ~ 275VAC @ 18 pcs of batteries
– Overload Capability : 1.5 In~1.8 In 30s~ 1h
– Short-circuit Capability : 1.8 In ~ >2.0 In 200ms~30s
EFFICIENCY
– Line Mode : 87%
– Battery Mode : 92%
BATTERY
– Standard Model Type : 12V / 9Ah
– Numbers : 16
– Typical Recharge Time : 6 hours recover to 90% capacity
– Long-run Model Type : Depending on the capacity of external batteries
– Numbers : 16 / 18
– Charging Current (max) : 2A/4A/8A (selectable)